An Innovative Air Conditioning System for Changeable Heat Loads

dc.contributor.authorTrushliakov, Eugeniy
dc.contributor.authorRadchenko, Mykola
dc.contributor.authorBohdal, Tadeush
dc.contributor.authorRadchenko, Roman
dc.contributor.authorKantor, Serhiy
dc.date.accessioned2021-09-07T08:44:46Z
dc.date.available2021-09-07T08:44:46Z
dc.date.issued2020
dc.descriptionAn Innovative Air Conditioning System for Changeable Heat Loads / E. Trushliakov, M. Radchenko, T. Bohdal, R. Radchenko, S. Kantor // Lecture notes in mechanical engineering. – 2020. – P. 616–625.uk_UA
dc.description.abstract1Abstract. The efficiency of air conditioning (AC) systems depends on the operation of their air coolers at varying heat loads in response to current changeable climatic conditions. In general case, an overall heat load of any AC system comprises the unstable range, corresponding to ambient air processing with heat load fluctuations, and a comparatively stable part for subsequent air subcooling. Following from this approach, a rational design overall heat load is chosen to provide a maximum annular refrigeration capacity generation and divided into a comparatively stable basic part and a remaining part for ambient air precooling at changeable heat loads. The ambient air precooling mode with considerable heat load fluctuation needs load modulation, whereas the comparatively stable heat load range can be covered by operation at about nominal mode. According to modern trend in AC systems the load modulation is performed by varying refrigerant feed to air coolers in Variable Refrigerant Flow (VRF) system. But with this the problem of inefficient operation of air coolers caused by dry-out of inner walls at the final stage of inside tube refrigerant evaporation followed by dropping the intensity of heat transfer remains unsolved. As alternative approach of the heat load modulation in AC systems there is a concept of incomplete refrigerant evaporation with overfilling air coils that leads to excluding a dry-out of inner surface of air coils and is realized through liquid refrigerant recirculation by injector (jet pump).uk_UA
dc.description.provenanceSubmitted by Диндеренко Катерина (kateryna.dynderenko@nuos.edu.ua) on 2021-09-07T08:42:31Z No. of bitstreams: 1 Trushliakov 21.pdf: 1051731 bytes, checksum: acb81a68e3f33c40b8a956f061f36e50 (MD5)en
dc.description.provenanceApproved for entry into archive by Диндеренко Катерина (kateryna.dynderenko@nuos.edu.ua) on 2021-09-07T08:43:27Z (GMT) No. of bitstreams: 1 Trushliakov 21.pdf: 1051731 bytes, checksum: acb81a68e3f33c40b8a956f061f36e50 (MD5)en
dc.description.provenanceApproved for entry into archive by Диндеренко Катерина (kateryna.dynderenko@nuos.edu.ua) on 2021-09-07T08:44:08Z (GMT) No. of bitstreams: 1 Trushliakov 21.pdf: 1051731 bytes, checksum: acb81a68e3f33c40b8a956f061f36e50 (MD5)en
dc.description.provenanceMade available in DSpace on 2021-09-07T08:44:46Z (GMT). No. of bitstreams: 1 Trushliakov 21.pdf: 1051731 bytes, checksum: acb81a68e3f33c40b8a956f061f36e50 (MD5)en
dc.identifier.issn2195-4356
dc.identifier.issn2195-4364
dc.identifier.urihttps://eir.nuos.edu.ua/handle/123456789/4325
dc.language.isoenuk_UA
dc.subjectAir conditioninguk_UA
dc.subjectHeat loaduk_UA
dc.subjectRefrigerant overfillinguk_UA
dc.titleAn Innovative Air Conditioning System for Changeable Heat Loadsuk_UA
dc.title22020
dc.typeArticleuk_UA

Файли

Контейнер файлів
Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
Trushliakov 21.pdf
Розмір:
1 MB
Формат:
Adobe Portable Document Format
Опис:
стаття
Ліцензійна угода
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
7.05 KB
Формат:
Item-specific license agreed upon to submission
Опис:

Зібрання